< 3. INSTALLATION, PIPING AND WIRING >
3-7
IM 12T03A01-02E
(1) Panel Mounting
The pipe mounting bracket should be removed from the converter before panel mounting.
Panel cutout dimensions are shown in Figure 3.9.
Before inserting the converter into front of the panel, remove the clumping brackets from both sides of
the converter case. After the case is inserted into a panel, remount the clumping brackets on the same
pace to hold the converter on the panel.
Figure 3.10 illustrates that the converter is mounted on a panel.
212 ±1
275 ±1
Unit: mm
Figure 3.9 Panel Cutout Dimensions
Figure 3.10 Panel Mounting