IM 01C21D01-01E
2-11
2. HANDLING CAUTIONS
Model
EJA110A
EJA120A
EJA130A
EJA130A
With code /PE3
EJA310A
EJA430A
EJA440A
EJA440A
With code /PE3
EJA510A
EJA510A
With code /PE3
EJA530A
EJA530A
With code /PE3
Category
*2
Article 3, paragraph 3
(SEP)
Article 3, paragraph 3
(SEP)
Article 3, paragraph 3
(SEP)
III
Article 3, paragraph 3
(SEP)
Article 3, paragraph 3
(SEP)
Article 3, paragraph 3
(SEP)
III
Article 3, paragraph 3
(SEP)
III
Article 3, paragraph 3
(SEP)
III
PS-V(bar-L)
1.6
0.005
4.2
4.2
1.6
1.6
50
50
50
50
50
50
V(L)
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
PS(bar)
*1
160
0.5
420
420
160
160
500
500
500
500
500
500
*1: PS is maximum allowable pressure for vessel itself.
*2: Referred to Table 1 covered by ANNEX II of EC Directive
on Pressure Equipment Directive 97/23/EC
T0299.EPS
(3) Operation
CAUTION
The temperature and pressure of fluid should
be applied under the normal operating condi-
tion.
The ambient temperature should be applied
under the normal operating condition.
Please pay attention to prevent the excessive
pressure like water hammer, etc. When water
hammer is to be occurred, please take mea-
sures to prevent the pressure from exceeding
PS by setting the safety valve, etc. at the
system and the like.
When external fire is to be occurred, please
take safety measures at the device or system
not to influence the transmitters.
2.12 Low Voltage Directive
Applicable standard : EN61010-1
(1) Pollution Degree 2
"Pollution degree" describes the degree to which a
soild, liquid, or gas which deteriorates dielectric
strength or surface resistivity is adhering. " 2 "
applies to normal indoor atmosphere. Normally,
only non-conductive pollution occurs. Occasionally,
however, temporary conductivity caused by
condenstaion must be expected.
(2) Installation Category I
"Overvoltage category(Installation category)"
describes a number which defines a transient
overvoltage condition. It implies the regulattion for
impulse withstand voltage. " I " applies to electrical
equipment which is supplied from the circuit when
appropriate transient overvoltage control means
(interfaces) are provided.