IM 1C22J1-01E
9-5
9. GENERAL SPECIFICATIONS
9.3 Optional Specifications
Item Description Code
Factory Mutual (FM)
CSA Explosionproof Approval
Explosionproof for Class I, Division 1, Groups B, C and D
Dustignitionproof for Class II/III, Division 1, Groups E, F and G
Division2 ‘SEALS NOT REQUIRED’ , Temp. Class : T4, T5, T6 Encl Type 4x
Max. Process Temp.: T4; 120 8C (248 8F), T5; 100 8C (212 8F), T6; 85 8C (185 8F)
Amb. Temp.:–40 to 80 8C (–40 to 176 8F)
Electrical connection: 1/2 NPT female
CF1
Canadian Standards
Association (CSA)
CSA Intrinsically safe Approval
Class I, Groups A, B, C and D Class II and III, Groups E, F and G
Encl Type 4x, Temp. Class: T4, Amb. Temp.: –40 to 60 8C (–40 to 140 8F)
Vmax=30 V, Imax=165 mA, Pmax=0.9 W, Ci=22.5 nF, Li=730 mH
Electrical connection: 1/2 NPT female
CS1
CENELEC (KEMA) Intrinsically safe Approval
EEx ia IIC T4, Amb. Temp.: –40 to 60 8C(–40 to 140 8F)
Ui=30 V, Ii=165 mA, Pi=0.9 W, Ci=22.5 nF, Li=730 mH
Electrical connection: 1/2 NPT female, Pg 13.5 female and M20 female
KS1
FM Intrinsically safe Approval
Intrinsically Safe for Class I, Division 1, Groups A, B, C & D, Class II, Division 1,
Groups E, F & G and Class III, Division 1 Hazardous Locations.
Nonincendive for Class I, Division 2, Groups A, B, C & D, Class II, Division. 2,
Groups E, F & G, and Class III, Division 1 Hazardous Locations.
Enclosure: “NEMA 4X”, Temp. Class: T4, Amb. Temp.: –40 to 60 8C (–40 to 140 8F)
Intrinsically Safe Apparatus Parameters
[Groups A, B, C, D, E, F and G]
Vmax=30 V, Imax=165 mA, Pmax=0.9 W, Ci=22.5 nF, Li=730 mH
[Groups C, D, E, F and G]
Vmax=30 V, Imax=225 mA, Pmax=0.9 W, Ci=22.5 nF, Li=730 mH
Electrical connection: 1/2 NPT female
FS1
CENELEC (KEMA) Flameproof Approval
EExd IIC T4, T5, T6, Amb. Temp.: –40 to 80 8C (–40 to 176 8F)
Max. process Temp.: T4; 120 8C (248 8F), T5; 100 8C (212 8F), T6; 85 8C (185 8F)
Electrical connection: 1/2 NPT female, Pg 13.5 female and M20 female
KF1
FM Explosionproof Approval
Explosionproof for Class I, Division 1, Groups B, C and D
Dust-ignitionproof for Class II/III, Division 1, Groups E, F and G
Hazardous (classified) locations, indoors and outdoors ( NEMA 4X )
Temperature class: T6
Amb. Temp.:–40 to 60 8C (–40 to 140 8F)
Electrical connection: 1/2 NPT female
FF1
Standards Association of
Australia (SAA)
SU1
SAA Flameproof, Intrinsically safe and Non-sparking Approval
Ex d IIC T4/T5/T6, IP67 class I, Zone 1, Amb. Temp. : –40 to 80 8C (–40 to 176 8F)
Max. Process Temp.: T4; 120 8C (248 8F), T5; 100 8C (212 8F), T6; 85 8C (185 8F)
Ex ia IIC T4, IP67 class I, Zone 0
Ex n IIC T4, IP67 class I, Zone 2
Ui=30 V DC, Ii=165 mA DC, Wi=0.9 W, Amb. Temp.: –40 to 60 8C (–40 to 140 8F)
Electrical connection: 1/2 NPT female, Pg 13.5 female and M20 female
FU1
Combined FF1and FS1
Electrical connection: 1/2 NPT female
Combined KF1, KS1 and Type N Approval
KEMA Type N Approval
Ex nA IIC T4, Amb. Temp.: –40 to 60 8C(–40 to 140 8F)
U=30 V, I=165 mA
Electrical connection: 1/2 NPT female, Pg 13.5 female and M20 female
KU1
CENELEC (KEMA)
CU1
Combined CF1 and CS1
Electrical connection: 1/2 NPT female
JF3
JS1
G11
G12
T0906.EPS
JIS Flameproof Approval, Ex do IIC T4X
Amb. Temp. –20 to 60
8C, Process Temp. –20 to 120 8C
JIS Intrinsically safe Approval, Ex ia IIC T4
Amb. Temp. –20 to 60
8C, Process Temp. –20 to 120 8C
Electrical connection: G1/2 female
Applicable cable O.D.: 8 to 12 mm
1 pc.
2 pcs.
Japanese Industrial
Standards (JIS)
Attached flameproof
Packing adapter