User's
Manual
DAQMaster MW100
Ethernet/IP Instruction Manual
2nd Edition: Apr. 2007
IM MW100EIP
DAQMaster MW100 Ethernet/IP Instruction Manual
Vista de pagina 0
1 2 3 4 5 6 ... 30 31

Indice de contenidos

Pagina 1 - User's

User'sManualDAQMaster MW100 Ethernet/IP Instruction Manual2nd Edition: Apr. 2007IM MW100EIPDAQMaster MW100 Ethernet/IP Instruction Manual

Pagina 2 - Table of Contents

10IM CA150ESpecifi cationThe following table describes how the MW100 conforms to the EIP specifi cation. Note that when interfacing to the MW100 on an

Pagina 3 - Introduction

11IM CA150ESummaryThe MW100 with EIP support can easily communicate via Explicit or I/O messaging to a variety of PLCs. The MW100 requires the PLC to

Pagina 4 - Explicit Messaging

12IM CA150EAppendix A – Detailed Explicit and I/O Messaging us-ing RSLogix®The majority of devices that the MW100 will be connected to using EIP will

Pagina 5

13IM CA150ERSLogix 500® Write MessageOnce the Control Block is designated, the Setup Screen can be confi gured. The fi rst item to fi ll in is the locat

Pagina 6 -

14IM CA150EWhen using RSLogix 500® with controllers such as the MicroLogix® series that have on board Ethernet support, the Setup Screen looks slightl

Pagina 7

15IM CA150EExplicit Messaging with RSLogix 5000®Explicit Messaging within RSLogix 5000® is similar to messaging in RSLogix 500® but there are a few di

Pagina 8

16IM CA150ENext confi gure the Communication Tab by entering the Path to the MW100. The Path can be designated by the name of the Ethernet port on the

Pagina 9

17IM CA150EI/O Messaging with RSLogix 5000®The fi rst step in confi guring an MW100 to communicate via I/O Messaging is to defi ne a connection within RS

Pagina 10 - Specifi cation

18IM CA150EWhen prompted, name the driver – in this case MW100 was used but the name can be changed to suit different naming conven-tions. Path name f

Pagina 11 - IM CA150E

19IM CA150EOpen RSLogix 5000® and select the PLC that is going to communicate with the MW100. Right click on Ethernet and select New Module... Adding

Pagina 12

2IM CA150ETable of ContentsTable of Contents ...

Pagina 13 - Write Message

20IM CA150EA defi nition screen should now appear for the ETHERNET-MODULE. In the Name fi eld – type MW100 (or the desired connection name). Comm For

Pagina 14

21IM CA150EI/O Confi guration within Controller Organizer tree – ETHERNET-MODULE MW100Browsing Controller Tags will now show MW100:I and MW100:O as tag

Pagina 15

22IM CA150EAppendix B – Detailed Confi guration of DigiOne IAP Serial GatewayFor PLCs that support serial communications via DF1 protocol, there are va

Pagina 16

23IM CA150EEnter the IP address and subnet mask that is desired. Confi guring IP Address of DigiOne IAPAfter confi guring the network settings choose Sk

Pagina 17

24IM CA150EThe default web browser should pop up with a prompt for a user name and password (if it does not automatically launch the web browser, then

Pagina 18

25IM CA150ESelect Industrial Automation Wizard link in the center of the screen to confi gure the IAP for an industrial network. Industrial Automation

Pagina 19

26IM CA150EThe fi rst source that will be setup is the interface for RSLinx® choose Allen-Bradley Ethernet and click Next. Click Next until the followi

Pagina 20

27IM CA150EGive the source a Description and confi gure the serial options to match the confi guration of the PLC, then click Next. Click Next until the

Pagina 21

28IM CA150EAddress 0 communications need to be retransmitted over the serial port connected to the SLC504®. Set Protocol to DF1 Full-Duplex and Seria

Pagina 22 - Serial Gateway

29IM CA150EThe next step is to tell the IAP where the MW100 is located and how to talk to it. Select Send messages to network device at Hostname – IP

Pagina 23

3IM CA150EIntroduction There is a large install base of industrial automation Programmable Logic Controllers (PLCs) and remote I/O that support Eth-er

Pagina 24

30IM CA150EIf all the settings match on the Summary page, click Finish to save the confi guration in the IAP. The IAP will then ask to be rebooted so a

Pagina 25

IM3E-2006.2Network Solutions Business DivisionInternational Sales Dept.Tachihi Bld. No.2, 6-1-3, Sakaecho, Tachikawa-shi,Tokyo 190-8586 JapanPhone: 81

Pagina 26

4IM CA150EExplicit MessagingExplicit Messaging is a point to point, request/response messaging protocol for unscheduled information transfer. In ladd

Pagina 27

5IM CA150EThe tables below detail the naming convention to use when creating explicit messages within RSLogix®. In the left most column is the native

Pagina 28

6IM CA150EWhen using RSLogix 5000® and RSLogix 500® there are different types of messages that correspond to the different type of PLCs. Everything f

Pagina 29

7IM CA150EI/O Messaging (Implicit Messaging)I/O Messaging, also known as Implicit Messaging, is used for point to point or multicast and to transmit a

Pagina 30

8IM CA150EBy clicking on ETHERNET-MODULE MW100 within the Controller Organizer tree, the connection can be fully confi gured. Note - the IP Address sh

Pagina 31 - IM3E-2006.2

9IM CA150EOnce an instance has been properly confi gured, the MW100 inputs and outputs will show up in the Controller Tags window. MW100 Channels withi