
IM DA100-11E
6-5
Commands
6
6.1 Setting Command
SL Sets an event/action.
Mode Operation mode
Release of event/action setting
Setting SLp1, p2<terminator>
p1 event/action box number (01 to 30)
p2 NONE
Event action setting by an alarm
Setting SLp1, p2, p3, p4, p5<terminator>
p1 Event action box number (01 to 30)
p2 Event (ALARM)
p3 Action mode (EDGE, LEVL)
p4 Action
ALARM_ACK Acknowledgement of
alarm status.
ALARM_RST Alarm reset
TIMER_RST Timer reset
MATH Computation start/stop/
reset/clear/group reset
REPORT Report start/stop
FLAG Set flag to 1
p5 Auxiliary action information (for
p3=EDGE)
• For p4=MATH
START Computation starts.
STOP Computation stops.
RESET Computed data are reset.
CLEAR Computed data are cleared.
RST_G01 to RST_G07
Computed data in the specified
group are clear.
• For p4=REPORT
START Report starts.
STOP Report stops.
• For p4=FLAG
F01 to F16:Specified flag number is set to 1.
p5 Auxiliary action information (for
p3=EDGE)
• For p4=FLAG
F01 to F16:Specified flag number is set to 1.
Event function setting by a remote, relay, timer, or
match time event
Setting SLp1, p2, p3, p4, p5, p6<terminator>
p1 Event action box number (01 to 30)
p2 Event (REMOTE, RELAY, TIMER,
MATCH_TIME)
p3 Auxiliary event information
• For p2=REMOTE, contact number (1 to 12)
• For p2=RELAY, the base unit + relay
number
• For p2=TIMER, timer number (1 to 6)
• For p2=MATCH_TIME, match time
number (1 to 3)
p4 Action mode (EDGE, LEVL)
p5 Action
ALARM_RST Alarm reset
TIMER_RST Timer reset
MATH Computation start/stop/
reset/clear/group reset
REPORT Report start/stop
FLAG Set flag to 1
p6 Auxiliary action information
• For p5=MATH
START Computation starts.
STOP Computation stops.
RESET Computed data are reset.
CLEAR Computed data are cleared.
RST_G01 to RST_G07
Computed data in the specified
group are clear.
• For p5=REPORT
START Report starts.
STOP Report stops.
• For p5=FLAG
F01 to F16:Specified flag number is set to 1.
Example Set an event action to start coputation when an
alarm occurs in event action box 02.
SL02, ALARM, EDGE, MATH, START
Comments • With an action as the start (event), another
action (action) can be executed automatically.
• Thirty types of event actions can be set.
• If the action mode is EDGE, the set action
continues even if the event action is over.
• If the action mode is set to LEVL , the set action
continues from the first event occurrence to the
next event occurrence.
• If the avtion mode is set to LEVL , the start/
stop/clear & start computation are disable.
• If the action is set to MATH, the edge and level
action cannot be set simultaneously.
• For details on an event/action, see the separate
manual (IMDP10001-61E).
SO Sets the computational expression.
Mode Operation mode
Setting SOp1, p2, p3, p4, p5, p6<terminator>
p1 Channel for computation:
Stand-alone model: A01 to A30
Expandable model: A01 to A60
p2 Computation on/off (on/off)
p3 Computational expression
(up to 40 characters)
p4 Span left value (-9999999 to 99999999)
p5 Span right value (-9999999 to 99999999)
p6 Position of decimal point for span (0 to 4)
Example Set the sum of channel numbers 001 and 002 to
channel A01 for computation. Set -10.0000 to
15.0000 for the span.
SOA01, ON, 001+002, -100000, 150000, 4
Comments • This command only works with the optional
computation function or if a pulse module is
installed.
• For details on operators, see the Appendix at
the end of this manual.
• If you wish to omit either p4, p5, or p6, omit
them all together.
• If pulse modules are installed and there is no
computation function, TLOG.PSOM will be the
only valid operator.
SK Sets the computational constants.
Mode Operation mode
Setting SKp1, p2 <terminator>
p1 Computational constant number:
Stand-alone model : K01 to K30
Expandable model : K01 to K60
p2 Constants
Example Set 300 to a computational constant K10.
SKK10, 300
Comments • This command is effective only with the
optional computation functions.
• Constant setting ranges are -1.0000E35 to
-1.0000E-35, 0, 1.0000E-35 to 1.0000E35.
Comentarios a estos manuales