Yokogawa Value Series FX1000 Manual de usuario Pagina 158

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 206
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 157
4-22
IM 04L21B01-17EN
Alarm Summary
The FL command is used to output the data.
The alarm summary is output. Up to 1000 alarm events are retained. Alarm events
that exceed 1000 are cleared from the oldest data.
Syntax
EACRLF
yy/mo/dd_hh:mm:ss_kkk_ccc_ls_nnnnnnnnnnCRLF
···································
ENCRLF
yy/mo/ddhh:mm:ss
Time when the alarm occurred
yy
Year (
00
to
99
)
mo
Month (
01
to
12
)
dd
Day (
01
to
31
)
hh
Hour (
00
to
23
)
mm
Minute (
00
to
59
)
ss
Second (
00
to
59
)
kkk
Alarm cause
OFF:
Alarm release
ON:
Alarm occurrence
ACK:
Alarm acknowledge
ccc
Measurement or computation channel number
l
Alarm level (
1
to
4
)
s
Alarm type (
H
,
h
,
L
,
l
,
R
,
r
,
T
, or
t
)
nnnnnnnnnn
Alarm sequence
_
Space
For all-channel alarms, the channel number, alarm level, and alarm status items
are all set to asterisk.
Example
EA
11/05/1112:20:00ON0011L 1
11/05/1112:30:00OFF1313t 2
11/05/1112:31:00OFF***** 3
11/05/1112:32:00ACK 4
EN
4.2 Output Format of Text Data
Vista de pagina 157