Yokogawa Value Series FX1000 Manual de usuario Pagina 61

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 206
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 60
1-53
IM 04L21B01-17EN
Using the Ethernet Interface (/C7 Option)
1
2
3
4
5
6
App
Index
Starting the Computation (FX1000 Client)
Press FUNC and select Math start.
The computation starts. A computation icon is displayed on the status display section.
The value of computation channel 101 displayed in group 1 on the FX1000 client
varies in sync with the measured value of channel 001 on the FX1000 server.
Confirming the Communication Status (FX1000 Client)
Showing a Menu to Switch to the Modbus Client Screen
This is the operation to show INFORMATION > MODBUS CLIENT on the display
selection menu.
Press MENU (to switch to setting mode), and select the Menu tab > Menu customize
> Display menu.
1.
Select INFORMATION > MODBUS CLIENT using the arrow keys.
Select INFORMATION > MODBUS MASTER when you use the Modbus master via the
serial communication.
2.
Press the View soft key.
The selected item displays in white.
View/Hide soft key
Toggles View and Hide each
time you press the soft key.
3.
Press ESC to return to the operation screen.
Displaying the Modbus Client Screen
Press DISP/ENTER and select INFORMATION > MODBUS CLIENT.
Select INFORMATION > MODBUS MASTER when you use the Modbus master via the serial
communication.
1.11 Usage Example of the Modbus Function
Vista de pagina 60
1 2 ... 56 57 58 59 60 61 62 63 64 65 66 ... 205 206

Comentarios a estos manuales

Sin comentarios