3.3 Reading Values Using Cursors
Procedure
1. On the waveform display window, click the tag of the group from which you wish to
read the value using cursors.
2. Click the position where you wish to read the data in the waveform display area of
the waveform display window.
If you wish to read another point simultaneously, drag the cursor. Cursor A
appears
at the position where you rst clicked; Cursor B appears at the position where you
released the mouse button. A yellow circle is displayed where the waveform and the
cursor cross.
Y
ou can move the waveform that is displayed in the waveform display area using the
scroll buttons or scroll bar.
Cursor A
Cursor B
Measurement
point
Group selection tab
3. From the Window menu, choose Control.
The Cursor Value window opens.
Channel number and
measurement unit
Channel display color
Time between Cursors A and B
Time at the Cursor B position
Time at the Cursor A position
Value at the Cursor B position – value at the Cursor A position
Value at the Cursor B position
Value at the Cursor A position
Alarm indication
Data number at the Cursor A position
Move
Cursor A
Data number at the Cursor B position
Move
Cursor B
Difference in the data number between Cursors A and B