Yokogawa DAQWORX Manual de usuario Pagina 114

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 336
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 113
5-18
IM WX104-01E
Channel (Setting the Burnout and RJC)
Click here (also selectable from [Setting] - [SETUP [Basic] Setting] - [Setting])
Set to the positive side (100%)
Set to the negative side (0%)
Set the reference junction compensation
to internal or external
Burnout
For thermocouple (TC) inputs, select how the measurement results are to be handled
when the thermocouple burns out.
RJC Volt (uV)
When the reference junction compensation is set to [External], set the compensation
value in the range from -20,000 to 20,000.
Copying and pasting setup data
The items checked in [Copy Details] can be copied and pasted. Click the channel
number to select the copy source or paste destination.
To select multiple channels to be copied, drag the channel number to specify the range
to be copied. To select multiple copy destinations, select the range in a similar fashion.
5.5 Configuring the Setup Mode