Configuring the CX1000/CX2000
Note
When the PV/SP math function is ON, the input settings are entered using [Control input
channel] items under the [Setting] tab. For the setting procedure, see page 8-10.
When the PV/SP Math Function Is ON
Enter PV or SP settings.
If the control mode is set to Retransmission, a menu for entering retransmission settings
appears. See the next page.
PV/SP Math Function
Select the item you wish to set, PV, PV1, PV2, or SP. If the control mode is set to Basic
or Cascade, set PV. If the mode is set to PVswitch, set PV1 and PV2. You can select
SP when [Internal loop] > [Remote setting] under the [Setup] tab is ON.
Mode
Select ON or OFF.
ON:
Enables the expression.
OFF: The control input channel below is assigned to the expression.
Control
mode
Basic Cascade PVswitch
(4 loops)
PVswitch
(6 loops)
PV SP PV(1) SP PV1 PV2 SP PV1 PV2 SP
Loop 1 CI01 CI02 CI01 CI02 CI01 CI02 CI03 CI01 CI02 CI01
Loop 2 CI04 CI05 CI04 CI04 CI05 CI01 CI04 CI05 CI01
Loop 3 CI06 CI07 CI06 CI07 CI06 CI07 CI08 CI06 CI07 CI01
Loop 4 CI09 CI10 CI09 CI09 CI10 CI01 CI09 CI10 CI01
Loop 5 CI03 CI01
Loop 6 CI08 CI01
Exp.
Enter the PV/SP expression. You cannot enter the expression if Mode is OFF.
8.4 Control Function General Settings